2017, SPAIN, WATER FOR INJECTION HEATER & COOLER

  • Home
  • /
  • 2017, SPAIN, WATER FOR INJECTION HEATER & COOLER

01/06/2017

  • Cooling 3.500 kg/h WFI from 80°C down to 25°C.
  • Heat exchanger multitubular ITMf type. Double tube sheet to avoid crossed contamination for Pharmaceutical applications.
  • Design according to ASME BPE.
  • RA ≤ 0,5 µm wetted parts.
  • Designed to be sanitized inside the inner tubes with steam.
  • Fully manufactured in SS 316L.
  • Vertical disposition.
  • Design Pressure 10 bar.
  • Design Temperature 180°C.

 

  • Heating 3.300 kg/h WFI to recover heat lost in pipes circulation.
  • Heat exchanger multitubular ITMf type. Double tube sheet to avoid crossed contamination for Pharmaceutical applications.
  • Design according to ASME BPE.
  • RA ≤ 0,5 µm wetted parts.
  • Designed to be sanitized inside the inner tubes with steam.
  • Fully manufactured in SS 316L.
  • Pitched dispositon for self-drainability.
  • Design Pressure 10 bar.
  • Design Temperature 180°C.
  • Location: Spain.